Temperature and concentration measurements in a high-pressure gasifier enabled by cepstral analysis of dual frequency comb spectroscopy
Keywords
Dual-comb spectroscopy, gasification, absorption spectroscopy, cepstral analysis, modified free-induction decay spectroscopy
Abstract
High-pressure gasification processes are important for conversion of solid materials into gaseous fuels and other chemicals. Laser absorption diagnostics are an important means to study these processes, but are challenging to implement due to the extreme temperatures and pressures present in the system. Here, we combine broadband high-resolution dual-comb spectroscopy with an advanced spectral absorption database and a new means for baseline-free absorption spectroscopy analysis to enable measurements of temperature and water vapor concentration in the core of an entrained flow gasifier operating at up to 1700 K and 15 bar. The dual-comb spectrometer measures the absorption of water vapor from 6800-7150 cm-1 with a point spacing of 0.0067 cm-1. The bandwidth is helpful for resolving the complex, congested absorption fingerprint of water vapor that is used to determine the species concentrations and temperature. We interpret the spectrum with absorption models based on a database measured under carefully controlled high-temperature conditions with the dual-comb spectrometer. The database includes the pressure broadening, shift, and temperature dependence of these parameters for water vapor in argon, which is the gasifier bath gas. Finally, fitting the absorption model to the data is enabled by modified free induction decay analysis, which is an approach for quantitatively obtaining species and temperature information without determining the baseline intensity of the spectrometer. The baseline-free approach is crucial to success in this environment, where there are no non-absorbing regions of the spectrum to anchor the normalization of the laser intensity as in traditional direct absorption spectroscopy. We demonstrate good agreement with temperatures measured on the reactor core via optical pyrometry, and show that water vapor concentrations in the reactor core did not reach the expected system set points during some experiments.
Original Publication Citation
P. J. Schroeder, Madison Kelley, et al., Temperature and concentration measurements in a high-pressure gasifier enabled by cepstral analysis of dual frequency comb spectroscopy, Proceedings of the Combustion Institute, vol. 38, no. 1, pp. 1561–1569, (Jan. 2021), doi https://doi.org/10.1016/j.proci.2020.06.011
BYU ScholarsArchive Citation
Porter, Jason M.; Schroeder, Paul J.; Makowiecki, Amanda S.; Kelley, Madison A.; Cole, Ryan K.; Malarich, Nathan A.; Wright, Robert J.; and Rieker, Gregory B., "Temperature and concentration measurements in a high-pressure gasifier enabled by cepstral analysis of dual frequency comb spectroscopy" (2021). Faculty Publications. 7103.
https://scholarsarchive.byu.edu/facpub/7103
Document Type
Peer-Reviewed Article
Publication Date
2021-1
Publisher
Elsevier
Language
English
College
Ira A. Fulton College of Engineering and Technology
Department
Mechanical Engineering
Copyright Status
© 2020 published by Elsevier
Copyright Use Information
https://lib.byu.edu/about/copyright/