Abstract

The promulgation of revised standards for atmospheric fine particles (PM2.5) by the US EPA has sparked renewed interest in the ability to accurately measure and characterize suspended atmospheric particulate matter. Semi-volatile material (SVM), consisting of ammonium nitrate and semi-volatile organic material (SVOM), is not accurately measured by EPA accepted methods such as the Federal reference method (FRM) or Tapered Element Oscillating Microbalance (TEOM). However, SVM is often a major fraction of urban aerosols. Recent advances in atmospheric sampling instrumentation allowed for the semi-continuous characterization of urban PM2.5, including SVM. The Filter Dynamic Measurement System (FDMS) was shown to measure total PM2.5 mass including semi-volatile species. Validation of the FDMS was performed by comparison with the particle concentrator-Brigham Young University organic sampling system (PC-BOSS) and the real-time total ambient mass sampler (RAMS). Semi-continuous ambient particulate concentrations of sulfate, nitrate and ammonium ion were measured by a newly developed Dionex instrument which was field tested and validated for the first time in Fresno, CA. Either a modified Sunset Laboratory carbon monitor, collocated with a conventional Sunset carbon monitor employing a common inlet, or the newly developed dual-oven Sunset monitor allowed for the semi-continuous determination of both nonvolatile and semi-volatile organic material. This was the first attempt to characterize both nonvolatile and semi-volatile fractions of an urban aerosol in a semi-continuous manner using all semi-continuous instruments. A suite of instruments for semi-continuous PM2.5 monitoring was recommended including, an R&P FDMS for the measurement of PM2.5 mass, a dual-oven Sunset monitor for the measurement of nonvolatile and semi-volatile carbonaceous species, and a Dionex GP-IC for the measurement of inorganic species. A TEOM monitor is also recommended to measure nonvolatile PM2.5 mass. Using these instruments, semi-continuous mass closure was obtained for the first time during a study conducted in Riverside, CA. The advantage of using semi-continuous sampler data in the application of source apportionment was elucidated. Local aerosols are often impacted by short-term pollution episodes that cannot be temporally resolved using integrated samplers. One-h averaged data applied to source apportionment models was shown to increase the power of the model to predict sources, both primary and secondary, that exhibit diurnal short-term episodes.

Degree

PhD

College and Department

Physical and Mathematical Sciences; Chemistry and Biochemistry

Rights

http://lib.byu.edu/about/copyright/

Date Submitted

2006-02-16

Document Type

Dissertation

Handle

http://hdl.lib.byu.edu/1877/etd1174

Keywords

particulate matter, PM2.5, fine particulate matter, air quality, semi-volatile material, semi-continuous instruments, aerosol science, FDMS, dual-oven Sunset Carbon monitor, source apportionment

Language

English

Share

COinS