Abstract
Noise from information technology (IT) equipment is a significant problem in today's modern society. Active Noise Control (ANC) has shown promise in reducing the effect of IT fan noise on users. Though ANC has been applied to axial fans (such as those found in desktop computers), it has not been applied to centrifugal fans, such as those found in laptop computers. This work applies an ANC method to a centrifugal fan mounted in a mock laptop enclosure. This method is applied in four steps. First, secondary sources are placed in the vicinity of the fan. Second, an accurate model of the radiation from the fan and secondary sources is constructed. Third, the total power radiated from this system is minimized. This creates nodal lines in the vicinity of the fan. Fourth, ANC error sensors are placed on the nodal lines predicted by the model. This creates these nodal lines experimentally, thus creating the minimum power condition. The noise from the exhaust and inlets of the fan will first be controlled individually. Then the method will be applied to the combined system. Global sound power radiation will be measured in all cases.
Degree
MS
College and Department
Physical and Mathematical Sciences; Physics and Astronomy
Rights
http://lib.byu.edu/about/copyright/
BYU ScholarsArchive Citation
Esplin, John J., "Active Noise Control of a Centrifugal Fan Mounted in a Mock Laptop Enclosure" (2012). Theses and Dissertations. 3577.
https://scholarsarchive.byu.edu/etd/3577
Date Submitted
2012-06-06
Document Type
Thesis
Handle
http://hdl.lib.byu.edu/1877/etd5273
Keywords
active noise control, ANC, centrifugal fan, sound power, laptop
Language
English