Abstract
Understanding glycemic response is necessary for preventing and managing the development of metabolic disease. The oral glucose tolerance test (OGTT) is a common clinical measure used to assess glucose tolerance in laboratory and clinical settings. An OGTT includes a 10-12 hour overnight fast, followed by the consumption of a 75g glucose beverage, concluding with a blood test(s) to measure postprandial glucose levels. This procedure usually requires participants to be present in the lab for temporary sessions and also requires drawing blood samples. Continuous glucose monitors (CGMs) also assess glycemic control and variability, but for multiple days at any location without the need of blood sampling. Because of this convenience, and recent over- the-counter availability of CGMs, we questioned whether a CGM could be used to create a modified OGTT capable of capturing chronic, free-living data in healthy people. To further reflect glucose challenges more likely to be presented in real life, we paired CGM monitors with a standard meal glucose challenge to create a meal glucose tolerance test (MGTT). The purpose of this study was to characterize the MGTT against an OGTT using area under the curve (AUC) and peak glucose (PG). We also assessed additional combinations of condition (the standard meal or 75g glucose drink) measured by test method (CGM or venous blood) to further explore the potential variations and applications of the MGTT. To do this, healthy college age participants (n=24) were asked to consume a standard meal and 75g glucose drink condition on separate occasions following a 10 hour overnight fast. The glycemic response of both of these conditions was captured by synchronized CGM and venous blood glucose measurements every 15 minutes during the post prandial period. Our results found that the AUC of the standard meal condition measured by CGM (MGTT) was not significantly different (p = 0.3020) and explained ~9% (r2 = 0.09) of the variance in the 75g glucose drink measured by venous blood (OGTT). The PG of MGTT was not significantly different (p = 0.9951) from the PG of an OGTT. The MGTT also explained ~36% (r 2 = 0.36) of the variance in OGTT. We found that the use of the 75g glucose drink when measured by CGM explained a relatively higher amount of variance in OGTT (~ 31% (r2 =0.31) (p < 0.001)). Overall, our results suggest that CGMs may be a useful tool in reflecting the AUC of an OGTT if a 75g glucose beverage is used as the glucose challenge.
Degree
MS
College and Department
Life Sciences; Nutrition, Dietetics, and Food Science
Rights
https://lib.byu.edu/about/copyright/
BYU ScholarsArchive Citation
Stallworth, Lindsey, "Characterization and Validation of a Meal Glucose Tolerance Test (MGTT)" (2025). Theses and Dissertations. 11461.
https://scholarsarchive.byu.edu/etd/11461
Date Submitted
2025-08-20
Document Type
Thesis
Permanent Link
https://arks.lib.byu.edu/ark:/34234/q2393117b8
Keywords
glucose monitoring, glycemic response, standard meal
Language
english